Weekly briefing
Overview is all history. Open latest week briefing (2025-W41)
Findings
7
Machines
3
Year-weeks
7
Defect codes
1
Latest week
2025-W41
1 findingsSame as previous week
Insights
Rule-based for now. The same cards can later come from an AI provider.
Prior week data is incompleteWatch
2025-W40 has no uploaded findings. New and cleared labels may be incomplete.
1 new finding not seen in the last 2 weeksNote
Raised in 2025-W41. Confirm against uploaded prior weeks before treating them as brand new.
Turntable Sensor is the leading defectWatch
Code 40 accounts for 7 of 7 findings (100%).
V4 carries most findingsWatch
V4 has 7 findings across 3 machines (100%).
V4.08 has the most problemsWatch
V4.08 (V4) has 5 of 7 findings (71%). Leading issue: Turntable Sensor (5).
Findings by week
Click a week to filter every panel
Machine × defect heatmap
Click a machine, code, or cell. Warmer cells have more findings. Swipe sideways on a phone to see more codes.
Defect codes
Most frequent codes in the current filters
Machine number
V4 machines in the current filters. Click a bar to open that machine.
Chronic repeats
Same machine and code in three or more consecutive weeks
No consecutive repeats in this view.
Findings
7 of 7 rows in the current filters
| Date | Week | Machine | Code | Problem |
|---|---|---|---|---|
| 2024-05-20 | 2024-W21 | V4.08 | 40 | Turntable Sensor |
| 2024-09-24 | 2024-W39 | V4.06 | 40 | Turntable Sensor |
| 2025-01-06 | 2025-W02 | V4.09 | 40 | Turntable Sensor |
| 2025-01-15 | 2025-W03 | V4.08 | 40 | Turntable Sensor |
| 2025-08-06 | 2025-W32 | V4.08 | 40 | Turntable Sensor |
| 2025-09-04 | 2025-W36 | V4.08 | 40 | Turntable Sensor |
| 2025-10-06 | 2025-W41 | V4.08 | 40 | Turntable Sensor |